محصولات ایرانی در حوزه ایمنی بسیار متنوع هستند
🎥 افتتاح ششمین همایش بین المللی ایمنی و آتشنشانی شهری
از بروز بودن تجهیزات سازمان آتش نشانی تهران شگفت زده شدم
🎥 ویدئو/آب در یک قدمی اصفهان بود که هلی کوپتر سقوط کرد!
لزوم توجه به عوامل موثر در تغییرات اقلیمی کشور
بومی سازی تکنولوژی روز دنیا در حوزه ایمنی را در دستورکار قرار دهیم
This standard contains minimum requirements for the design, installation, and maintenance of foam-water sprinkler and spray systems. These systems shall be designed with the required density for either foam or water application as the controlling factor, depending on the design purpose of the system.
This standard provides the minimum requirements for the design, installation, and system acceptance testing of water spray fixed systems for fire protection service and the minimum requirements for the periodic testing and maintenance of ultra-high-speed water spray fixed systems.
his standard covers the minimum requirements for the installation of standpipes and hose systems.
This standard shall cover the design and installation of automatic sprinkler systems for protection against fire hazards in residential occupancies up to and including four stories in height that are located in buildings not exceeding 60ft (18m) in height above grade plane.
This recommended practice provides basic procedures and information for use in fire department operations concerning properties equipped with certain fixed fire protection systems. The fixed systems covered in this recommended practice are interior automatic sprinkler systems, exterior sprinkler systems, and standpipe systems.
This standard shall cover the design, installation, and maintenance of automatic sprinkler systems for protection against the fire hazards in one- and two-family dwellings, manufactured homes, and townhouses.
This standard shall provide the minimum requirements for the design and installation of automatic fire sprinkler systems and exposure protection sprinkler systems covered within this standard
This standard contains minimum requirements for total flooding Halon 1301 fire extinguishing systems. It includes only the essentials necessary to make the standard workable in the hands of those skilled in this field. Only those skilled in this work are competent to design, install, maintain, decommission, and remove this equipment.
This edition of NFPA 12, Standard on Carbon Dioxide Extinguishing Systems, was prepared by the Technical Committee on Gaseous Fire Extinguishing Systems. It was issued by the Standards Council on March 18, 2021, with an effective date of April 8, 2021, and supersedes all previous editions.
This edition of NFPA 11C, Standard for Mobile Foam Apparatus, was prepared by the Technical Committee on Foam and acted on by the National Fire Protection Association, Inc. at its Annual Meeting held May 22-25, 1995 in Denver, CO.