کل 26857
2

Comparison of technical and economic efficiency of extended aeration and sequencing batch reactors processes in hospital wastewater treatment

  • کد خبر : 4380
  • 18 اردیبهشت 1397 - 0:00
Comparison of technical and economic efficiency of extended aeration and sequencing batch reactors processes in hospital wastewater treatment

توضیحات :

Journal of Advances in Environmental Health Research

 

Volume 4, Issue 1, Winter 2016

 

Authors : Arezoo Heidari , Mahdi Sadeghi , Abotaleb Bay , Jalal Keihanpour , Elham Omidi , Khadijeh Bay , Mahmoud Tabatabaei

 

Abstract :

Wastewater of hospitals can cause many risks to public health due to having a variety of pathogenic microorganisms, pharmaceutical substances, and other hazardous toxic substances. The aim of this study was to evaluate the chemical quality of effluents from wastewater treatment plant of Falsafi Hospital and Hakim Jorjani Hospital in Gorgan, Iran, and to compare them technically and economically. This descriptive-analytical study was performed on 64 samples of raw wastewater entrance and output effluent obtained from treatment plants using extended aeration process and sequencing batch reactors (SBR) in two hospitals in Gorgan. All experiments for determination of pH, free residual chlorine, biochemical oxygen demand (BOD), chemical oxygen demand (COD), and total suspended solids (TSS) were performed using standard methods. Finally, the obtained data were analyzed using t-test and Mann-Whitney test in SPSS software. Based on the results, the removal efficiency of BOD, COD, and TSS of the extended aeration system was 91, 90.8, and 95.7 percent, respectively, while these values for the SBR system were found to be 91.7, 91.9, and 95.3 Percent, respectively. Moreover, in the output of the two hospitals, pH values were recorded as 6.69 ± ۰.۲۶ and 7.33 ± ۰.۲ and the average amount of free residual chlorine was 0.12 and 0.13 mg/l, respectively. This study demonstrates good performances of the extended aeration activated sludge system and the SBR system in terms of reduction of pollution load to its standard limits for agriculture and irrigation purposes. However, due to slightly better efficiency, lower cost of investment, and operation compared to other methods, the SBR system is recommended.

 

Keyword : Hospital Wastewater, Extended Aeration, Sequencing Batch Reactor, Iran

 

<< Read more in the attachment>>

Please use the link below to download the article ” Comparison of technical and economic efficiency of extended aeration and sequencing batch reactors processes in hospital wastewater treatment “.

File download

لینک کوتاه : https://hsenk.ir/?p=4380

ثبت دیدگاه

مجموع دیدگاهها : 0
قوانین ارسال دیدگاه
  • دیدگاه های ارسال شده توسط شما، پس از تایید توسط تیم مدیریت در وب منتشر خواهد شد.
  • پیام هایی که حاوی تهمت یا افترا باشد منتشر نخواهد شد.
  • پیام هایی که به غیر از زبان فارسی یا غیر مرتبط باشد منتشر نخواهد شد.